|
|
AN-500S /AN-500B
DANPEX CORPORATION
AN-500S /AN-500B
|
NIC Type
|
ARCnet
|
|
Transfer Rate
|
2Mbps
|
|
Data Bus
|
8-bit ISA
|
|
Topology
|
Star (AN-500S)
Linear Bus (AN-500B)
|
|
Wiring Type
|
Shielded/Unshielded twisted pair
RG62A/U 93ohm coaxial
|
|
Boot ROM
|
Available
|
|
NODE ADDRESS
|
|
Node
|
SW2/1
|
SW2/2
|
SW2/3
|
SW2/4
|
SW2/5
|
SW2/6
|
SW2/7
|
SW2/8
|
|
0
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
-
|
|
1
|
On
|
On
|
On
|
On
|
On
|
On
|
On
|
Off
|
|
2
|
On
|
On
|
On
|
On
|
On
|
On
|
Off
|
On
|
|
3
|
On
|
On
|
On
|
On
|
On
|
On
|
Off
|
Off
|
|
252
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
On
|
On
|
|
253
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
On
|
Off
|
|
254
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
On
|
|
255
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
Off
|
|
Note: Node address 0 is used for messaging between nodes and must not be used.
A total of 255 node address settings are available. The switches are a binary representation of the decimal node addresses. Switch 8 is the Least Significant Bit and switch 1 is the Most Significant Bit. The switches have the following decimal values: switch 8=1, 7=2, 6=4, 5=8, 4=16, 3=32, 2=64, 1=128. Turn off the switches and add the values of the off switches to obtain the correct node address. (On=0, Off=1)
|
|
RESPONSE AND RECONFIGURATION TIMEOUTS
|
|
Response Time
|
Idle Time
|
Reconfiguration Time
|
JP1
|
JP2
|
|
78µs
|
86µs
|
840ms
|
Open
|
Open
|
|
285µs
|
316µs
|
1680ms
|
Closed
|
Open
|
|
563µs
|
624µs
|
1680ms
|
Open
|
Closed
|
|
1130µs
|
1237µs
|
1680ms
|
Closed
|
Closed
|
|
Note: All NICs on the network must have this option set the same.
|
|
INTERRUPT REQUEST
|
|
IRQ
|
JP3
|
JP4
|
JP5
|
JP6
|
JP7
|
JP8
|
JP9
|
JP10
|
JP11
|
JP12
|
JP13
|
|
2
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
|
3
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
4
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
|
5
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
|
6
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
|
7
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
|
10
|
Open
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
11
|
Open
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
12
|
Open
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
14
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
15
|
Open
|
Closed
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
Open
|
|
ONBOARD TERMINATOR
|
|
Setting
|
JP14
|
| »
|
Disabled
|
Open
|
|
|
Enabled
|
Closed
|
|
Note:If the card is the last in the line of network cards, the onboard terminator may be enabled instead of using a T-connector and an external terminator. This setting is valid only with the AN-500B. If using model AN-500S, JP14 must be open. (Star topologies do not require the use of terminators)
|
|
CARD TYPE
|
|
Card
|
JP15
|
|
AN-500S
|
Open
|
|
AN500B
|
Closed
|
|
I/O BASE ADDRESS
|
|
Address
|
SW1/1
|
SW1/2
|
SW1/3
|
SW1/4
|
SW1/5
|
SW1/6
|
| »
|
2E0h
|
Off
|
On
|
Off
|
Off
|
Off
|
On
|
|
|
2F0h
|
Off
|
On
|
Off
|
Off
|
On
|
Off
|
|
|
300h
|
Off
|
Off
|
On
|
On
|
On
|
On
|
|
RIM BUFFER ADDRESS
|
|
Address
|
SW1/7
|
SW1/8
|
SW1/9
|
SW1/10
|
|
|
C0000 - C07FFh
|
Off
|
Off
|
On
|
On
|
| »
|
D0000 - D07FFh
|
Off
|
Off
|
On
|
Off
|
|
|
E0000 - E07FFh
|
Off
|
Off
|
Off
|
On
|
|
DIAGNOSTIC LED(S)
|
|
LED
|
Status
|
Condition
|
|
LED1
|
On
|
Card is receiving power and is operating properly
|
|
LED1
|
Flashing
|
Data is being transmitted or received
|
|
LED1
|
Off
|
Card is not receiving power or is defective
|
|